*    BioVec Force Platform Systems for Gait and Balance

BioVec systems are available with from one to four force platforms.  BioVec systems are aggressively priced to provide a significant savings over the cost of the aggregate system components.  Purchasing a BioVec system not only provides you with the best price but also assures you that you will get all of the necessary components, instrumentation and software required to setup your gait or balance laboratory.

Several turnkey BioVec systems are available, each employing a different signal conditioning technology or strategy. The following table presents a brief comparison of the available BioVec systems. Click on the system of interest for more information.

BioVec System Configurations

BioVec Standard

BioVec-Standard includes from one to four AMTI MiniAmps to provide front-end signal conditioning.

BioVec Internal

BioVec-Internal is configured using AMTI's force platforms equipped with internal strain gage amplifiers.

BioVec Premium

BioVec-Premium includes one to four AMTI DigiAmps, AMTI's premium strain gage amplification and signal conditioning system. DigiAmp's provide dual outputs for Ethernet and or legacy analog applications. An internal high power DSP provides digital filtering and intelligent circuit compensation to achieve the most stable accurate strain gage amplifier available today. For user convenience all amplifier settings including gain, excitation voltage and filter cutoff frequencies are software controlled.

BioVec Standard

AMTI's BioVec Standard system is an analog force platform system used by hundreds of gait labs around the world. The BioVec Standard is available with up to four AMTI force platforms each with a companion MiniAmp strain gage amplifier. The MiniAmp amplifiers provide the necessary strain gage bridge excitation (jumper selectable 2.5, 5 and 10 Volts), front-end filter factory set at 1000 Hz and jumper selectable gains at 1000, 2000 and 4000. The high level analog outputs of the MiniAmps are routed to AMTI's ADI-32 interconnection box from which they are then routed to a PCI bus data acquisition card (DT 3002) mounted in a PC. The PC and peripherals are not supplied with the BioVec system.  The BioVec Standard system provides a very economical and dependable gait lab solution.

The BioVec Standard system is shipped with AMTI's NetForce data acquisition software and AMTI's BioAnalysis gait and balance analysis software.

BioVec Internal

AMTI's BioVec Internal system is an analog force platform system which uses AMTI's platforms equipped with internal strain gage amplifiers. The BioVec Internal is available with up to four AMTI force platforms, where each platform has it's own self contained strain gage amplifier. The internal amplifiers are similar to AMTI's MiniAmp and provide the necessary strain gage bridge excitation (jumper selectable 2.5, 5 and 10 Volts), front-end filter factory set at 1000 Hz and jumper selectable gains at 1000, 2000 and 4000. (See the platform options selection in the Platform home page for more information). The high level analog outputs of the platforms are routed to AMTI's ADI-32 interconnection box and on to a PCI bus data acquisition card (DT 3002) mounted in a PC. The PC and peripherals are not supplied with the BioVec system.

The BioVec Internal system also includes AMTI's NetForce data acquisition software and BioAnalysis gait and balance analysis software.

BioVec Premium

AMTI's BioVec Premium system is dual output system providing both digital and analog force platform outputs. BioVec Premium uses up to four AMTI DigiAmps to provide amplification and signal conditioning. BioVec premium provides the ultimate in user convenience and is recommended for high throughput gait labs where maximizing system flexibility and minimizing setup and testing time are important considerations. All amplifier settings are maintained by a PC running the NetForce software, this ensures concordance between the amplifier hardware and software settings and simplifies gain, excitation and filter settings.

Gain settings from 1000 to 8000 and excitation voltage settings between 0 and 10 volts (in 1/16th volt increments) allow you to optimize the systems dynamic range depending on the subjects body weight. As the settings are maintained and changed on the PC you may quickly shift from settings optimized for small children to adults in a few seconds. If your laboratory is engaged in both balance and gait work then the software adjustable filters will permit you to switch from a low frequency balance setting to a higher frequency gait setting with a few mouse clicks.

The BioVec Premium system also includes AMTI's NetForce data acquisition software and BioAnalysis gait and balance analysis software.

The BioVec Premium system is a state of the art gait lab solution and is ideal for gait labs where efficiency and flexibility are of critical importance.

The DigiAmp Difference

The DigiAmp is not just an amplifier, it is a complete high speed, high accuracy, signal conditioning and data acquisition front-end for strain gage bridge instrumentation. It is perfectly matched for use with AMTI's force platforms and transducers. The DigiAmps internal circuitry provides the following functions:

*       Strain gage amplifier

*       Bridge excitation

*       Data acquisition (A/D conversion)

*       Anti-aliasing filters

*       Software adjustable digital filters

*       A complete amplification and signal conditioning front-end

Stability, Accuracy and Repeatability

The DigiAmps exacting hardware and firmware design provides the highest stability, lowest noise strain gage signal conditioning platform available today. Built in quality features include:

*       Matched resistor packs on ceramic substrate for thermal and humidity stability

*       Active front-end components with lowest possible theoretical noise floor

*       Internal EMI cages and isolation

*       Extensive ground plane isolation

*       Inductive and capacitive ground plane passivation

*       High stability, high linearity 16 bit A/D conversion

*       Internal self measurement of critical parameters

*       Built in compensation, calibration and correction algorithms

*       Lead wire resistance compensation

*       Four KV front-end ESD protection

Operating Flexibility and Ease of Use

The DigiAmp is designed for a smooth transition from the legacy world of analog signal conditioning to the modern world of digital instrumentation. The DigiAmp provides both analog and Ethernet outputs allowing you to interface with existing analog data acquisition systems while planning for a future transition to the convenience and reliability of digital data acquisition and signal conditioning. Some of DigiAmp's many user interface features include:

*       Ethernet output for simple connection to a PC or Laptop

*       Software coordinated setup and control via Ethernet interface

*       Cascade up to six amplifiers on a single Ethernet line

*       Analog outputs for legacy applications

*       Stand alone key pad and LCD interface for legacy applications

*       Software adjustable gains (1000, 2000, 4000, and 8000)

*       Software adjustable bridge excitation (0 to 10 volts in 1/16th volt increments)

*       Software filters( Bessel or Butterworth, 10, 20, 30, 50, 100, 200, 300, 500, 1000 Hz)

*       Software auto zero

*       Software internal calibration
        

 

 